Product code
| DPS | 01 | R | ||
| Series Cod | Measurement Range 10:Positive Pressure (-0.1-1.0MPa) 01:Mixed Pressure (-100-100KPa) 00:Negative Pressure (0-101KPa) | Port R:R1/8 (M5X0.8 internal thread) | Output Method N1:NPN 1 Output P1:PNP 1 Output N2:NPN 2 Output P2:PNP 2 Output C:NPN 1 Output(Analog Voltage Output) D:NPN 1 Output(Analog Current Output) RS:Modbus Protocol RS485 Interface, Single-Channel Switch Output(NPN/PNP) | Option A:with metal bracket AM:with plastic panel mounting bracket MS:with plastic panel mounting bracket&transparent protective cover |
Oil Resistant Rubber Insulated Flexible Wire Specifications


Panel Introduction

| Serial number | Name | Serial number | Name |
| 1 | Pressure unit | 6 | Upward Adjustment Keys |
| 2 | Group 1 switching output indicator | 7 | Setting Function Keys |
| 3 | Main display (pressure/setting) | 8 | Downward adjustment key |
| 4 | Secondary display (function setting) | 9 | Electrical connections |
| 5 | Group 2 switching output indicator | 10 | Pressure connection |
Standard Specifications
| Model | DPS-200 (negative pressure) | DPS-201 (mixed pressure) | DPS-210 (positive pressure) | |
| Rated pressure range | 0.0~-101.0 KPa | -100.0~100.0 KPa | -0.100~1.000 MPa | |
| Set pressure range | 10.0~-105.0KPa | -105.0-105.0 KPa | -0.105~1.050 MPa | |
| Pressure-resistant test pressure | 500 KPa | 500 KPa | 1.5MPa | |
| Setting minimum unit | 0.1 KPa | 0.1KPa | 0.001 MPa | |
| Suitable Fluid | Air, non-corrosive gas, non-flammable gas | |||
| Supply voltage | DC12-24V±10%, fluctuation (P-P) 10% or less (with reverse connection protection) | |||
| Current consumption | 40mA or less | |||
| Switching output | NPN or PNP open collector 1 output | |||
| Maximum applied pressure | NPN or PNP open collector 2 output (optional) | |||
| Maximum load current | 28V (at NPN output) | |||
| Residual Voltage | 80mA | |||
| Response time | 1V or less (at 80mA load current) | |||
| Short circuit protection | 2.5ms or less (Selection from 20, 100, 500, 1000, 2000ms for shock prevention function) | |||
| Repeatability | Short-circuit protection function | |||
| hysteresis | hysteresis mode | Variable from 0” | ||
| Upper and lower limit comparison mode | ||||
| Display Mode | 4-digit 7-segment LCD 2-color display (red/green) | |||
| analogOutputs(voltage) ² Analog outputvoltage) ² | Output Voltage(Rated pressure range) | 1-5V±2.5%F.S. | 0.6-5V±2.5%F.S. | |
| Linearity | ±1%F.S. | |||
| Output Impedance | 约1K Q | |||
| analogOutputs(ElectricalCurrent) ³ | Output Current(Rated pressure range) | 4-20mA±2.5%F.S | 2.4-20mA±2.5%F.S. | |
| linearity | ±1%F.S | |||
| Load Impedance | Maximum load impedance: power supply voltage 12V: 3000; power supply pressure 24V: 6000; minimum load impedance: 500 | |||
| Display Accuracy | ±0.2%F.S±1digit (at 25±3°C ambient temperature) | |||
| Motion Indicator | Lamp on when switch ON, OUT1:Green, OUT2:Red | |||
| Environment | Protection level | IP40 | ||
| Temperature range | Operating: 0~50℃, Storage: -10~60℃ (non-condensing and non-freezing) | |||
| Operating humidity range | Working, preservation: 35-85% (non-condensing) | |||
| Withstanding Voltage | AC1000V 1 minute (between charging place and case) | |||
| Insulation resistance | 50MQ or more (DC500V megohmmeter, between the charging place and the shell) | |||
| Vibration | 10-150Hz full amplitude 1.5mm or 20m/s² (whichever is smaller) in each direction of XYZ for 2 hours (uncharged) | |||
| Shock resistance | 100m/s² XYZ 3 times in all directions (uncharged) | |||
| Temperature Characteristics | ±2%F.S. (based on temperature 25°C) | |||
| Conductors | Oil-resistant vinyl rubber insulated cable 3 cores 3.5,2m4 cores conductor cross section 0,15 mm² (AWG26), insulator O.D. 1,0 mm | |||
| Tube caliber | R1/8 M5×0.8(standard), material: C3602 nickel-platedNPT1/8 M5×0.8(standard),Material:C3602 nickel plated. | |||