Model Number Indication
Standard Specifications
Bore ( mm ) | 6 | 10 | 15 | 20 | 25 | 32 | 40 | ||
Fluid to be used | Air | ||||||||
Action type | Double acting | ||||||||
Maximum operating pressure | 0.7MPa | ||||||||
Minimum operating pressure | 0.18MPa | ||||||||
Ambient and fluid temperature | -10~+60℃(but not frozen) | ||||||||
Piston Speed | 50~1000mm/s | ||||||||
Cushioning | Rubber buffer/hydraulic buffer at both ends (optional) | ||||||||
Stroke tolerance mm | 0~250: +1.00 | 251~1000:+1.40 | 1001~:+1.8 0 | ||||||
*Feed oil | Unnecessary | ||||||||
Tube bore Rc | M8×0.8 | 1/8 | 1/4 | ||||||
Mounting position | limitless |
Stroke/magnetic switch options
Bore (mm) | Standard Stroke(mm) | longest Stroke (mm) | Magnetic switch model Rail installation |
6 | 50,100,150,200 | 300 | A73 |
10 | 50,100,150,200,250,300 | 500 | |
15 | 50,100,150,200,250 300,350,400,450,500 | 750 | |
20 | 50,100,150,200,250 300,350,400,450, 500,600,700,800 | 1000 | |
25 | 1500 | ||
32 | |||
40 | 50,100,150,200,250 300,350,400,450,500 600,700,800,900,1000 |
Note 2)For specifications and features of magnetic switches, please refer to the series of magnetic switches.
After the model number of the magnetic switch, there is a symbol for the length of the wire: No symbol: -0.5m, L-3m, Z-5m.Example: A73, A73L
Maximum load and stroke
External Dimension (mm)
● CY1L6,10
Model | Stroke range | A | B | C | D | d | EA | EB | EA | FB | G | GP | H | HA | HB | HG | HI | HO | HP | HS | HT |
CY1L6 | ~300 | 7 | 6.5 | 3 | 7.6 | 8 | – | – | – | – | 6 | 36 | 27 | 6 | 10 | 11 | 9 | 25 | 26 | 14 | 16 |
CY1L10 | ~500 | 8.5 | 8 | 4 | 12 | 10 | 6 | 12 | 3 | 5 | 7.5 | 50 | 34 | 6 | 17.5 | 14.5 | 13.5 | 33 | 33 | 21.5 | 18 |
Model | J | JK | L | LD | M | MM | N | (NA) | (NB) | NN | *PA | PB | PW | Q | QW | RW | T | TT | ta | tb | W | Z |
CY1L6 | M4×0.7 | 6.5 | 40 | 3.5 | 6 | M4×0.7 | 10 | 30 | 24 | M8×1.0 | 24 | 40 | 60 | 54 | 20 | 12 | 10 | 16 | 一 | 一 | 56 | 68 |
CY1L10 | M5×0.8 | 9.5 | 68 | 4.3 | 8 | M4×0.7 | 9.5 | 27 | 19 | M8×1.0 | 30 | 60 | 80 | 85 | 26 | 17.5 | 12.5 | 20.5 | 0.5 | 1.0 | 77 | 103 |
* The center of the dimension of PA is the same as the center of the dimension of L
● CY1L15,20,25,32,40
Model | Travel range | A | B | C | D | d | EA | EB | FA | FB | G | GP | H | HA | HB | HG | HI | HO | HO | HS | HT | J | JK | L | LD | ||
CY1L15 | ~750 | 7.5 | 9.5 | 5 | 16.6 | 12 | 6 | 13 | 3 | 6 | 6.5 | 65 | 40 | 6.5 | 4 | 16 | 14 | 38 | 39 | 25 | 16 | M6×1.0 | 9.5 | 75 | 5.6 | ||
CY1L20 | ~1500 | 9.5 | 9.5 | 5.2 | 21.6 | 16 | 一 | 一 | 一 | 一 | 8.5 | 80 | 46 | 9 | 10 | 18 | 16 | 44 | 45 | 31 | 20 | M6×1.0 | 10 | 86 | 5.6 | ||
CY1L25 | ~1500 | 9.5 | 11 | 6.5 | 26.4 | 16 | 8 | 14 | 4 | 7 | 8.5 | 90 | 54 | 9 | 18 | 23 | 21 | 52 | 53 | 39 | 20 | M8×1.25 | 10 | 86 | 7 | ||
CY1L32 | ~1500 | 10.5 | 14 | 8 | 33.6 | 20 | 8 | 16 | 5 | 7 | 9.5 | 110 | 66 | 12 | 26.5 | 26.5 | 24.5 | 64 | 64 | 47.5 | 25 | M10×1.5 | 15 | 100 | 9.2 | ||
CY1L40 | ~1500 | 11.5 | 14 | 8 | 41.6 | 25 | 10 | 20 | 5 | 10 | 10.5 | 130 | 78 | 12 | 35 | 30.5 | 28.5 | 76 | 74 | 56 | 30 | M10×1.5 | 15 | 136 | 9.2 |
Model | M | (N) | (NA) | (NB) | NN | P | *PA | PB | PW | Q | QW | RW | T | ta | tb | TT | W | Z | Hydraulic buffers |
CY1L15 | 8 | 7.5 | 27 | 17 | M8×1.0 | M5×0.8 | 45 | 70 | 95 | 90 | 30 | 15 | 12.5 | 0.5 | 1.0 | 22.5 | 92 | 112 | RB0805 |
CY1L20 | 10 | 10 | 29 | 20 | M10×1.0 | Rc(PT)1/8 | 50 | 90 | 120 | 105 | 40 | 28 | 16.5 | 一 | 一 | 25.5 | 117 | 130 | RB1006 |
CY1L25 | 10 | 11 | 49 | 40 | M14×1.5 | Rc(PT)1/8 | 60 | 100 | 130 | 105 | 50 | 22 | 16.5 | 0.5 | 1.0 | 25.5 | 127 | 130 | RB1411 |
CY1L32 | 12 | 11.5 | 52 | 42 | M20×1.5 | Rc(PT)1/8 | 70 | 120 | 160 | 121 | 60 | 33 | 18.5 | 0.5 | 1.0 | 28.5 | 157 | 149 | RB2015 |