Products

  • Home
  • Products
  • Magnetically Coupled Rodless Cylinder CY3S Series (Φ6-Φ63)

Magnetically Coupled Rodless Cylinder CY3S Series (Φ6-Φ63)

Share to:

Model Number Indication

Standard Specification

Bore( mm )61015202532405063
Fluid UsedAir
Operation methodDouble acting
Maximum operating pressure0.7MPa
Minimum operating pressure0.18MPa
Ambient and fluid temperature-10~60℃(but not frozen)
Piston speed50~400mm/s
*CushioningRubber cushioning on both ends
Stroke tolerance mm0~250:,251~1000:。4,1001~:
**Feed oilUnnecessary
Tube caliberM5×0.8Rc1/8Rc1/4
Mounting positionlimitless
*Optional hydraulic buffer (slide rule type only – CY1S)
*If lubrication is required, use Turbine 1 oil ISOVG32.

Stroke/magnetic switch options

BoreStandard Stroke(mm)Maximum stroke(mm)Magnetic Switch Models
(rail mounted, slide
rule type only)
Basic typeSlide rule type
650,100,150,200300300A73
1050,100,150,200,250,300500500
1550,100,150,200,250,
350,400,450,500
750
20100,150,200,250,300,
350,400,450,500,600,
700,800
1000
251500
32
40100,150,200,250,300,
350,400,450,500,600,
700,800,900,1000
*Non-standard travel is available.
*Magnetic switch specifications and characteristics can be found in the Magnetic Switch Series.
Wire length indication symbol: no symbol -0.5mm, L-3m, Z-5m Example: A73, A73L
 

Theoretical output force of cylinder and magnetic couple holding force

Bore
( mm)
ModelHolding forceH-shape(N)Magnetic coupling holding forceCorresponding pressure(Mpa)Maximum operating pressure when stopping in the middle of the stroke(Mpa)
φ6CY1□6H19.60.70.55
φ10CY1□10H53.90.70.55
φ15CY1□15H137.30.790.65
φ20CY1□20H2310.760.65
φ25CY1□25H362.80.750.65
φ32CY1□32H588.40.740.65
φ40CY1□40H921.80.750.65

Maximum load and stroke (CY1S)

If the center of gravity of the load and the slider is at the same point, the relationship curve between force and stroke is as shown in the figure below. When using the cylinder, try to make the center of gravity of the load and the slider as close as possible. If it is impossible, please contact our company.

External Dimension (mm)

● Basic type (C□Y1S6-10)
ModelTravel rangeφDφdAφBCHTGGPHHAHGHPHSTJ×KLLDM
CY1S6
CDY1S6
~3007.6866.53175322719826810M4×0.7×6.5403.56
CYS10
CDY1S10
~30012107.584186.5403425.512331412.5M5×0.8×9.5454.36
ModelMMNN(N)P*PAPBPWQWQSTTZW
CY1S6
CDY1S6
M4×0.7M8×1.010M5×0.8252550165242166846
CY1S10
CDY1S10
M4×0.7M8×1.09.5M5×0.825386024604720.58058
Note) Magnetic switch can also be mounted on the A side.
*Dimension center of PA is the same as dimension center of L.
● C□Y1S15·20•25•32•40
ModelStroke range φDφdAφBCHTGGPHHAHGHPHSDTJ×KLLDM
COY1S15~75016.6127.59.55216.552402913391512.5M6×1.0×9.5605.68
COY1S20~150021.616109.55.2208.5624636174525.516.5M6×1.0×9.5705.610
COY1S25~150026.41610116.5208.570544020535316.5M8×1.25×1070710
COY1S32~150033.62012.5148249.586664624642718.5M10×1.5×15858.712
C□Y1S40~150041.62512.51482510.5104765725743020.5M10×1.5×  15958.712
ModelMMNN(N)P*PAPBPWQWQSTTZW
C口Y1S15M5×0.8M8×1.07.5M5×0.830507530756222.59772
C口Y1S20M6×1.0M10×1.09.51/840709038907325.511587
C口Y1S25M6×1.0M14×1.5111/8407010042907325.511597
C口Y1S32M8×1.25M20×1.511.51/84075122501109128.5138119
C□Y1S40M8×1.25M20×1.510.51/865105145641209935.5155142
*Dimension center of PA is the same as dimension center of L.
Note) Magnetic switch can also be mounted on the A side.