Model Number Indication

Standard Specification
| Model | 4E1 | 4E2 | 4E2C.P.R |
| Piping Caliber Code | 8A | ||
| Piping Caliber Size | G1/4 | ||
| Number of Square Ports | 5 口 | ||
| Number of Positions | 2 position | 3 position | |
| Used Fluid | Air | ||
| Operating Pressure Range | 0.2~0.8MPa | 0.3~0.8MPa | |
| Operating Pressure Range(LP) | 0~0.8MPa | ||
| External guide pressure(LP) | 0.2~0.8MPa | 0.3-0.8MPa | |
| Pressure resistance | 1MPa | ||
| Effective fracture area | 18mm² | 16mm² | |
| Ambient temperature | -5~+50℃ (non-freezing) | ||
| Response time | 40ms | ||
| Fixed voltage | AC110V,220V(50/60)Hz,DC24V | ||
| Power consumption | AC=4.8/4.4VA,6/4.9VA DC=3W | ||
| Voltage tolerance range | ±10% | ||
| Insulation class | Level F | ||
| Weight | 228g | 314g | 444g |
Flow Rate Characteristics

External specifications